- This topic has 1 reply, 2 voices, and was last updated 7 years ago by .
Viewing 2 posts - 1 through 2 (of 2 total)
Viewing 2 posts - 1 through 2 (of 2 total)
- You must be logged in to reply to this topic.
Home › Forums › General › AS1554 Questions › incomplete penetration procedures
hi ppl.
can anyone tell me if you can use a pqr which is qualified full pen welded both sides 10mm plate single v on a welded joint which is not full pen or welded both sides eg. shs or
i do understand that there are joint id for incomplete penetration. its just on the job there not using a pqr that is for incomplete penetration.
thanks
jez
The procedure should be requalified for partial penetration for several reasons:
1/ The root face has obviously been increased.
2/ The weld preparation shape has been changed.
3/ The required depth of penetration has not been proven by macro.